DynaMesh®

Tailored Implants made of PVDF

DynaMesh®-SIS direct
DynaMesh®-SIS direct soft
DynaMesh®-SIS direct visible

For the surgical treatment of stress and mixed urinary incontinence

Transobturatoric position of the tape, in “outside-in” technique.
Outstanding shape stability, defined elasticity, high effective porosity and atraumatic selvedges [21].


Transobturator (outside-in)

DM-SIS-transobturatoric

Videos: DynaMesh®-SIS direct & DynaMesh®-SIS direct soft - Transobturator

Videos: DynaMesh®-SIS direct & DynaMesh®-SIS direct soft

(–) – Animation:
DynaMesh®-SIS direct & DynaMesh®-SIS direct soft – TOT 8/4

(en) – Animation & Operation:
DynaMesh®-SIS direct soft – TOT 8/4 – The Surgical Treatment of Urinary Stress Incontinence (Dr. Jäger)

(en) – Animation & Operation:
DynaMesh®-SIS direct -Transobturator Sling (Dr. Richter)

(–) – Animation:
DynaMesh®-SIS direct soft – Transobturator (out/in)

(en) – Animation & Operation:
DynaMesh®-SIS direct soft for Surgical Treatment oft Stress and Mixed Urinary Incontinence (Dr. Anding)

Associated instruments - Transobturator (outside-in)

DynaMesh®-IST03
Chirurgisches Instrument
d 5 cm
REF IST03F1
VE = 1 Satz (l+r)


instrumente-IST01

DynaMesh®-IST01
Chirurgisches Instrument
d 6 cm
REF IST01F1
VE = 1 Satz (l+r)


instrumente-IST02

DynaMesh®-IST02
Chirurgisches Instrument
d 7 cm
REF IST02F1
VE = 1 Satz (l+r)


instrumente-IVT01

DynaMesh®-IVT01
Chirurgisches Instrument
REF IVT01F1
VE = 1 Stück

DynaMesh®-SIS direct

DynaMesh®-SIS direct soft
with SOFT structure

DynaMesh®-SIS direct visible
with SOFT structure
+ visible on MRI


Product range
sis-direct-v

DynaMesh®-SIS direct
01 cm x 50 cm PV211050F1 Unit = 1 EA / BX
DynaMesh®-SIS direct
01 cm x 50 cm PV211050F3 Unit = 3 EA / BX
DynaMesh®-SIS direct soft
01 cm x 50 cm PV411050F1 Unit = 1 EA / BX
DynaMesh®-SIS direct soft
01 cm x 50 cm PV411050F3 Unit = 3 EA / BX
DynaMesh®-SIS direct visible
01 cm x 50 cm PV471050F1 Unit = 1 EA / BX
DynaMesh®-SIS direct visible 01 cm x 50 cm PV471050F3 Unit = 1 EA / BX

 

Use and properties
Product DynaMesh®-SIS direct (1)

DynaMesh®-SIS direct soft (2)

DynaMesh®-SIS direct (3)

Field of application stress urinary incontinence (SUI) /
mixed urinary incontinence (MUI)
Surgical method transvaginal / transobturator
Fixation none
Optimal handling
gruene_punkte
Optimal patient safety
gruene_punkte
Optimal patient comfort
gruene_punkte
Atraumatic selvedges
gruene_punkte
No curling up
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
visible technology
graue_punkte (1,2) / gruene_punkte (3)

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Technical data
Product DynaMesh®-SIS direct (1)

DynaMesh®-SIS direct soft (2)

DynaMesh®-SIS direct (3)

Polymer (Monofilament) PVDF
Excellent biocompatibility
gruene_punkte
Minimal foreign body reaction
gruene_punkte
Reduced bacterial adherence
gruene_punkte
High ageing resistance
gruene_punkte
Optimal dynamometry
gruene_punkte
Reactive surface (a) [m²/m²] 2.8 (1)

2.2 (2,3)

Maximum stability (b) [N/cm] 117 (1)

76 (2,3)

Elasticity (b) at 16 N/cm [%] 6 (1)

9 (2,3)

Textile porosity (c) [%] 63 (1)

70 (2,3)

Effective porosity (c) [%]] 57 (1)

67 (2,3)

Effective porosity at 2.5/16 N/cm(c) [%] 57/59 (1)

67/68 (2,3)

Classification (d) 1a

gruene_punkte Applies to all product sizes

Legends for the technical data

(a) Ratio of implant reactive surface area (thread surface) to implant surface area
(b) measured in the strip tensile test
(c) Mühl method [6]
(d) Klinge’s classification [8]