DynaMesh®

Tailored Implants made of PVDF

DynaMesh®-SIS
DynaMesh®-SIS soft
DynaMesh®-SIS visible

For the surgical treatment of stress and mixed urinary incontinence

Retropubic and transobturatoric position of the tape in “inside-out” and “outside-out” technique.
Outstanding shape stability, defined elasticity, high effective porosity and atraumatic selvedges [21].

 


Retropubic (inside-out)

DM-SIS-retrosymphysary

Associated instruments - Retropubic (inside-out)

instrumente-ISR01

DynaMesh®-ISR01
Surgical instrument
REF ISR01F1
Unit = 1 pc.

Videos: DynaMesh®-SIS & DynaMesh®-SIS soft (Retropubic)

Videos: DynaMesh®-SIS & DynaMesh®-SIS soft

(–) – Animation:
DynaMesh®-SIS & DynaMesh®-SIS soft – Surgical treatment of stress urinary incontinence with DynaMesh®-SIS soft in retrosymphyseal technique

(en) – Animation & Operation:
Surgical treatment of stress urinary incontinence with DynaMesh®-SIS soft in retrosymphyseal technique (Dr. Böing)

Transobturator (outside-in)

DM-SIS-transobturatoric

Associated instruments - Transobturator (outside-in)

instrumente-IST03

DynaMesh®-IST03
Surgical instrument
d 5 cm
REF IST03F1
Unit= 1 set (l+r)


instrumente-IST01

DynaMesh®-IST01
Surgical instrument
d 6 cm
REF IST01F1
Unit= 1 set (l+r)


instrumente-IST02

DynaMesh®-IST02
Surgical instrument
d 7 cm
REF IST02F1
Unit= 1 set (l+r)


instrumente-IVT01

DynaMesh®-IVT01
Surgical instrument
REF IVT01F1
Unit = 1 pc.


DynaMesh®-SIS

DynaMesh®-SIS soft
with SOFT structure

DynaMesh®-SIS visible
with SOFT structure
+ visible on MRI


Product range

sis-v

DynaMesh®-SIS 01 cm x 50 cm PV211056F1 Unit = 1 EA / BX
DynaMesh®-SIS 01 cm x 50 cm PV211056F3 Unit = 3 EA / BX
DynaMesh®-SIS soft
01 cm x 50 cm PV411056F1 Unit = 1 EA / BX
DynaMesh®-SIS soft
01 cm x 50 cm PV411056F3 Unit = 3 EA / BX
DynaMesh®-SIS visible
01 cm x 50 cm PV471056F1 Unit = 1 EA / BX
DynaMesh®-SIS visible 01 cm x 50 cm PV471056F3 Unit = 3 EA / BX
Use and properties
Product DynaMesh®-SIS (1)

DynaMesh®-SIS soft (2)

DynaMesh®-SIS visible (3)

Field of application stress urinary incontinence (SUI) /
mixed urinary incontinence (MUI)
Surgical method transvaginal / retropubic / transobturator
Fixation none
Optimal handling
gruene_punkte
Optimal patient safety
gruene_punkte
Optimal patient comfort
gruene_punkte
Atraumatic selvedges
gruene_punkte
No curling up
gruene_punkte
Shape stability
gruene_punkte
Defined elasticity
gruene_punkte
visible technology
graue_punkte (1,2) / gruene_punkte (3)

gruene_punkte Applies to all product sizes
gaue_punkte Does not apply

Technical data
Product DynaMesh®-SIS (1)

DynaMesh®-SIS soft (2)

DynaMesh®-SIS visible (3)

Polymer (Monofilament) PVDF
Excellent biocompatibility
gruene_punkte
Minimal foreign body reaction
gruene_punkte
Reduced bacterial adherence
gruene_punkte
High ageing resistance
gruene_punkte
Optimal dynamometry
gruene_punkte
Reactive surface (a) [m²/m²] 2.8 (1)

2.2 (2,3)

Maximum stability (b) [N/cm] 117 (1)

76 (2,3)

Elasticity (b) at 16 N/cm [%] 6 (1)

9 (2,3)

Textile porosity (c) [%] 63 (1)

70 (2,3)

Effective porosity (c) [%]] 57 (1)

67 (2,3)

Effective porosity at 2.5/16 N/cm(c) [%] 57/59 (1)

67/68 (2,3)

Classification (d) 1a

gruene_punkte Applies to all product sizes

Legends for the technical data

(a) Ratio of implant reactive surface area (thread surface) to implant surface area
(b) measured in the strip tensile test
(c) Mühl method [6]
(d) Klinge’s classification [8]